Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: QNE350A
Brand: QUANNING
Current Type: Dc
Rated Insulation Voltage: 1200
Rating Voltage: ≤900
Rated Operating Current: 350
Transportation: Ocean
Place of Origin: NANJING,CHINA
Certificate: CE
Port: SHANGHAI
Payment Type: L/C
Incoterm: FOB
NanJing QuanNing Electric Co., Ltd.
QNE350A High Voltage DC Contactor
QNE350A High Voltage Dc Contactor is used for auxiliary electrical switching control of electric vehicle, precharge control, electric vehicle, fast charging pile, battery switching and high voltage DC voltage switching control of electric motorcycle, circuit protection and safety control, etc.
;
350A+ charging capacity, can rupture 2000A current at 320VDC; Small size, light weight.
The switch part and the driving part are inflated and sealed to cut off the high-capacity load.
Fully sealed structure, high safety; Non-oxidation coils and contacts can be used in explosive or harmful environments, even for a long time;.
Product standard:IEC60947-4, GB14048.4
Certification: CE
| QNE350A-G1-24 | |
contact | Rated Insulation Voltage Ui(V) | 1200 |
rating voltage Ue(V DC) | ≤900 | |
Conventional thermal current Ith(A) | 350 | |
Rated operating current Ie(DC-1 A) | 350 | |
resistance | ≤2mΩ (12VDC/10A) | |
MAX Voltage switching | 1200VDC | |
MAX Current switching | 2000A/320V | |
Overload cut-off | 320VDC 下 2000A,1 320VDC 200A Once | |
contact form | Bridge 1NO |
7、
Do not touch the Relay terminal when it is energized or in danger of electric shock
Disconnect the load voltage when the voltage withstand test is conducted on the control circuit and non-metallic materials
Avoid installing the product in places with strong magnetic fields (transformers or magnets) or near objects with heat radiation
Do not stick sundries and oil stains on the main outgoing terminal, and the external lead terminal shall be in reliable contact with the main outgoing terminal, otherwise the terminal will be heated seriously and the connecting cable will melt
Please drive the coil through step power supply instead of making the voltage rise slowly during the action voltage test
Install within the specified range. The tightening torque of the screws at the load installation position is9~11N ·m; The tightening torque of the screws at the installation position of the contactor is4~5N ·m
Do not use the relay in case of accidental drop and impact
Product Categories : DC Contactor > High Voltage DC Contactor
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.